Metro TMT Fe 550D is our most ductile Fe 550-grade bar. The "D" stands for ductility. Fe 550D has all six core qualities of Fe 550, and its chemistry and mechanical performance are refined further for structures that must withstand sudden, unpredictable forces such as earthquakes and floods.
Core Qualities (shared with Fe 550)
- Better bonding with concrete
- Easy welding and fire resistance up to 500°C
- Seismic resistance
- Consistent, precise quality
- Corrosion resistance
- High fatigue resistance
Additional Fe 550D Advantages
- Higher Ductility: Elongation of 15.5% (against 12% for Fe 550) lets the bar stretch and absorb far more energy before failure, which is important during earthquakes.
- Lower Sulphur and Phosphorus: Combined S+P is only 0.065%, compared with 0.085% in Fe 550 and an IS limit of 0.075% for Fe 550D. Lower impurities give tougher, more reliable steel.
- Lower Carbon and Carbon Equivalent: Carbon is 0.230% and carbon equivalent is 0.450%, against an IS limit of 0.610%. This gives better weldability and toughness.
- Higher Strength Reserve: A TS/YS ratio of at least 1.10 and tensile strength of at least 615 N/mm² provide a larger safety margin between yielding and failure.
- Guaranteed Total Elongation: Minimum total elongation of 6% (against an IS requirement of 5%) gives assured performance under extreme loads.
- Designed for Seismic Zones: Together, these properties make Fe 550D a strong choice for high-rises and critical structures in earthquake-prone areas.
Technical Properties (IS 1786:2008)
Property |
IS Requirement |
Metro TMT Fe 550D |
Carbon (max %) |
0.250 |
0.230 |
Sulphur (max %) |
0.040 |
0.035 |
Phosphorus (max %) |
0.040 |
0.035 |
Sulphur + Phosphorus (max %) |
0.075 |
0.065 |
Carbon Equivalent (max %) |
0.610 |
0.450 |
Yield Stress (min, N/mm²) |
550 |
560 |
Tensile Strength (min, N/mm²) |
600 |
615 |
TS/YS Ratio (min) |
1.08 |
1.10 |
Elongation (min %) |
14.5 |
15.5 |
Total Elongation (min %) |
5 |
6 |